Skip to main content
Win32 Appsdecimal -2016410839

Fix Intune Error 0x87D00329

Requirement evaluation or detection failed — a requirement, dependency or supersedence rule does not resolve, so the app never reaches the installer.

Open the log below first. It is the quickest way to confirm which of the causes applies before you change anything.

AppIntentEval.log

Folder: C:\Windows\CCM\Logs\

Also check: AppDiscovery.log · AppEnforce.log

Root causes

  • A requirement rule references a file, registry value or OS version the device does not have.
  • A dependency app failed or is not applicable on this device.
  • A supersedence rule points at a superseded version that no longer resolves.
  • The app was revised and the requirement was evaluated against stale policy.

Step-by-step remediation

  1. In AppIntentEval.log find the failed requirement, dependency or supersedence rule and its state.
  2. Check the rule against the device: does the file, registry value or OS condition actually hold?
  3. Fix the rule, or the dependency or supersedence chain, rather than the installer — the installer never ran.
  4. Run the Machine Policy Retrieval and Application Deployment Evaluation cycles, then retry on a pilot device.

For the full diagnosis around this error, read ConfigMgr app failing: content or detection?.

Stop it happening on the next package

Most Win32 failures are decided by the detection rule and the install command, so fix them at the source before the app is assigned again.

Other Win32 Apps errors with their own runbooks.

Search all 46 error codes