ConfigMgr / MECMdecimal -2016410009
Fix Intune Error 0x87D00667
No current or future service (maintenance) window exists to install the update — the window is too small for the maximum run time, or the client never received the window policy.
Open the log below first. It is the quickest way to confirm which of the causes applies before you change anything.
WUAHandler.log
Folder: C:\Windows\CCM\Logs\
Also check: UpdatesDeployment.log
Root causes
- The maintenance window on the client is shorter than the deployment’s maximum run time.
- No maintenance window is assigned to the device or collection.
- The client never received the window policy.
- The window exists but is in the past, and none is scheduled.
Step-by-step remediation
- In WUAHandler.log and UpdatesDeployment.log find the service-window check and the window the client sees.
- In the console, check the maintenance windows on the device collection and confirm one covers the deployment’s maximum run time.
- Run Machine Policy Retrieval on the client and confirm the window policy arrives.
- Lengthen the window, or shorten the run time, then retry the deployment.
For the full diagnosis around this error, read Prove which service owns Windows Update on a co-managed device.
Keep patching failures out of the queue
Repeat update and client failures are cheaper to prevent than to chase. Compare the options that take app packaging and upkeep off your task list, from Enterprise App Management to PSADT.
Compare Win32 packaging toolsRelated Error Codes in This Category
Other ConfigMgr / MECM errors with their own runbooks.
- 0x87D00321The install did not finish inside the "Maximum allowed run time", so Configuration Manager timed it out and failed the deployment.
- 0x87D00607The client could not find the application content on any distribution point it can reach (content not found).
- 0x8004100EA WMI namespace the client needs is missing (WBEM_E_INVALID_NAMESPACE), typically root\ccm, so the ConfigMgr client is broken.
- 0x87D00692A higher authority, normally a domain Group Policy, overrides the Windows Update settings ConfigMgr tries to apply, so software update scans fail.
- 0x87D1076CThe application was successfully installed — reported as an error code, but it means success, so do not chase it as a failure.
- 0x87D00202The Configuration Manager client service was shutting down while the app action ran, so the deployment could not complete.
- 0x87D01201The content download could not run because there is not enough free space in the client cache or the disk is full.